Inside LM TEK 4U8GPU10KW

Engineered as one thermal and power system.

The chassis is built around the cooling loop, the PCIe slot layout follows the loop’s physical envelope, and power distribution is platform-level. It is not a board dropped into a case; it is a platform designed as a single engineering problem.

A barebone platform: LM TEK supplies the chassis, the integrated cooling loop, and platform-level power. You specify the board, CPUs, GPUs, memory, and storage.

01 · Subsystem

Density

Liquid cooling collapses each GPU’s thermal solution into a single-slot water block. That, not a bigger box, is how eight full-height PCIe Gen 5 cards fit in a 4U envelope.

The chassis is engineered around standard EATX server motherboards rather than a proprietary board. PCIe slot positions and clearance accommodate the cooling loop without needing custom riser cards. Mounting hardware is rack-standard. The platform takes ordinary enterprise components and arranges them at extraordinary density.

Rated Value
GPU slots Up to 8 × full-height PCIe Gen 5
Form factor 4U · 19-inch rack chassis
LM TEK 4U8GPU10KW from above with the cover removed: eight GPU slots beside the manifold
Top view, cover removed. Shown populated; the platform ships as a barebone.

02 · Subsystem

Upgrade in place

The chassis, loop, and power are sized for the full eight-GPU end state on day one. A two-GPU entry build grows inside the same chassis and on the same loop, in the same four rack units.

A supported accelerator comes from the published compatibility list, with its water block. Anything outside the list is a bespoke project with LM TEK engineering.

Supported boards, sockets and GPUs →
Rated Value
Entry build Two GPUs
End state Eight full-height PCIe Gen 5 GPUs
CPU Single-socket to dual-socket is a board choice
Exploded view of the LM TEK 4U8GPU10KW: chassis, cooling loop, GPU blocks and power supplies

03 · Subsystem

The loop

The chassis is built around the closed cooling loop, and the PCIe slot layout follows the loop’s physical envelope rather than a board form factor. Pump, manifold, GPU and CPU water blocks, radiator, and reservoir all live inside the chassis, with the radiator on the front intake so airflow paths are engineered alongside the loop.

Maximum working pressure for the assembled loop is 0.6 bar, set by the radiators. There is no external CDU or facility plumbing.

Rated Value
Loop type Closed integrated loop, fully in-chassis
Radiator placement Monolith triple-width pass-through radiator · front intake; airflow paths engineered alongside the loop
Radiator core 130 mm thick core · 120 × 360 mm standard cooling surface · fits 3 × 120 mm standard fans per side
Fans 6 × industrial-grade fans
An open test unit seen from above: manifold, eight GPU block lines, radiator and fans inside one chassis
A test unit with the cover removed: the whole loop sits inside the chassis.

04 · Subsystem

The blocks

The loop uses the materials discipline, pressure envelope, and manifold geometry of the LM TEK liquid-cooling catalogue, transferred to enterprise rack scale. Cooling designed by the EK engineering team, twenty-five years deep in high-performance liquid cooling.

Block availability is part of the published compatibility list.

Compatible components →
Rated Value
Coolant materials stack Nickel-plated copper · stainless steel · POM Acetal · EPDM · brass · EK-CryoFuel
GPU and CPU water blocks Matched to the chosen GPUs and CPUs

05 · Subsystem

Platform power

80 PLUS Titanium PSUs, 5 × 2 kW with redundancy, and a platform-level PDU size the GPU power budget at the chassis, not the board.

The customer’s motherboard chooses CPU and memory; the platform chooses how power reaches the GPUs.

Rated Value
Power supply 5 × 2 kW with redundancy · CRPS · 80 PLUS Titanium
Power distribution Platform-level PDU · independent of motherboard VRM
PSU redundancy 5 × 2 kW with redundancy · implemented by the platform PDU
Rear of the LM TEK 4U8GPU10KW: the row of five power supplies under the exhaust grille

06 · Subsystem

Control and protection

The server preset holds the coolant at 50°C at the hottest point in the loop, which favours sustained performance. For the controller revision and monitoring integration in a given deployment, talk to LM TEK engineering.

Protective functions are integral to safe operation: the system shuts down at 60°C coolant temperature, performs a hard shutdown if either pump fails, and boots only when at least one pump reports function. Do not bypass or disable these protections.

An audible alarm signals fan failure. Investigate and resolve the alarm before continued operation.

Reported controller behaviour Value
Coolant temperature target Server preset universal at 50°C at the hottest point in the loop
Coolant temperature System shutdown at 60°C coolant temperature
Pump failure Hard shutdown on failure of either pump
Boot interlock System boots only when at least one pump reports function
Fan failure Audible alarm on any fan failure
Exploded view of the LM TEK 4U8GPU10KW: loop, fans, power supplies and chassis

07 · Subsystem

Service and access

Dry-break quick disconnects support block replacement with the server racked. Integrated IN/OUT service ports provide access for an automated drain, flush and fill cycle without opening the loop. Front fill access and the reservoir window provide access and visibility.

Available integration resources →
Rated Value
Serviceability Dry-break front quick-disconnect couplings · built-in coolant level indicator (reservoir window)
Storage bay Single mounted drive bay for 5 × 2.5-inch drives · in chassis airflow path · positioned for straightforward access during service
Front of the LM TEK 4U8GPU10KW: slot covers, I/O and the reservoir window

A published compatibility list; bespoke projects with engineering.

The platform ships with a published compatibility list: supported board formats and sockets, GPUs with available water blocks, and the operating limits. A configuration built from it is quotable as is. Anything outside it, such as another GPU or a custom cooling solution, is a bespoke project with LM TEK engineering.

Modification projects →

LM TEK d.o.o. · Pod Lipami 10 · 1218 Komenda · Slovenia

Get in touch

Partner with LM TEK

Request information

We usually respond within a day or two. Your details stay with LM TEK and are not shared with partners until you confirm the introduction.

Send a platform enquiry

You are (optional)

Talk to an engineer

Choose which categories LM TEK may set. Strictly necessary cookies keep the site working and cannot be switched off here. Your choice is stored for 12 months and you can change it at any time from the footer.

Cookie Policy